Configuration Including Peripheral Equipment - Mitsubishi Electric Melservo MR-J5-G Series User Manual

Hide thumbs Also See for Melservo MR-J5-G Series:
Table of Contents

Advertisement

1.5

Configuration including peripheral equipment

• Do not connect these connectors to other than specified network. Otherwise, a malfunction may occur.
• Equipment other than the servo amplifier and servo motor is optional or recommended products.
The following is an example using MR-J5-20G-RJ.
R S T
Power supply
Molded-case
circuit breaker
(MCCB)
Magnetic
contactor
(MC)
*1
Line noise filter
(FR-BSF01)
L1
L2
L3
Power factor
P3
improving
DC reactor
(FR-HEL)
P4
P+
Regenerative
option
C
*1 The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
*2 This is for the MR-J5-_G-RJ servo amplifier. MR-J5-_G servo amplifier does not have CN2L connector. If using MR-J5-_G-RJ servo
amplifier in the linear servo system, connect an external encoder to this connector. Refer to the following for the compatible external
encoders.
Page 24 Parts identification
U
V
W
L11
L21
CN1A
CN1B
MR Configurator2
CN5
CN6
Analog monitor
CN8
Safety relay
CN3
Junction terminal block
CN2
*2
CN2L
Servo motor
1 SPECIFICATIONS
1.5 Configuration including peripheral equipment
1
Controller or
servo amplifier
Controller or
servo amplifier
Personal
computer