1. FUNCTIONS AND CONFIGURATION

1.6 Configuration including peripheral equipment

CAUTION

1.6.1 For MR-J4-_A4(-RJ)

(1) MR-J4-200A4(-RJ) or less
The diagram is for MR-J4-60A4-RJ and MR-J4-100A4-RJ.
R S T
(Note 2)
Power supply
Molded-case
circuit breaker
(MCCB)
(Note 3)
Magnetic
contactor
(MC)
(Note 1)
Line noise filter
(FR-BSF01)
Power factor
improving DC
reactor
(FR-HEL-H)
Regenerative
option
Connecting a servo motor for different axis to U, V, W, or CN2 of the servo
amplifier may cause a malfunction.
POINT
Equipment other than the servo amplifier and servo motor are optional or
recommended products.
L1
L2
U
L3
V
P3
W
P4
P+
C
L11
L21
CN5
CN6
CN3
CN8
CN1
CN2
CN2L (Note 4)
CN4
1 - 27
Personal
computer
MR Configurator2
Analog monitor
Personal computer and others
To safety relay or
MR-J3-D05 safety
logic unit
Junction terminal block
Battery
Servo motor