If the LED is off, it may indicate one of the problems listed in the following table:

Table 4: Wireless Signal LED Diagnostics

Symptom
Possible Problem
Obstructions in the propagation path
Weak RF
causing signal degradation.
Link
Antenna moved, due to high winds.
Ethernet Link LED
The Link LED lights solid green when there is an Ethernet connection and no traffic, and
blinks when traffic is detected. If the LED is off, it may indicate one of the problems listed
in the following table:

Table 5: Ethernet Link/Act LED Diagnostics

Symptom
Possible Problem
Poor cable connection to Ethernet
No Ethernet
equipment.
Link
Wrong type of cable to Ethernet
equipment.
System processor malfunction.
The connected Ethernet equipment
may be malfunctioning.
Ethernet 100 LED
The Ethernet 100 LED lights solid green when the Ethernet port is operating at 100 Mb/s
and is off when operating at 10 Mb/s. If the LED is off, it may indicate one of the
problems listed in the following table:
Symptom
Possible Problem
AN-80i is manually set for
Ethernet 10
10Base-T operation and
Mbps
connected device is operating at
100Base-T or auto-negotiate.
The connected Ethernet device is
operating at 10Base-T.
70-00072-01-07
Proprietary Redline Communications © 2008
&
AN-80i

Table 3: Wireless Signal LED Indication

The Wireless Signal LED lights solid green when the wireless link is
operating at the rate equal to the Uncoded Burst Rate setting, and
blinks when operating at a lower rate.
The Wireless Signal LED lights solid green when the wireless link is
established.

Table 6: Ethernet 100 LED Diagnostics

Solution
Try to remove obstacles or re-locate
antenna.
Re-align the antenna.
Solution
Carefully check all cable connections.
If the Ethernet is connected to a
router, a straight-through cable is
required. If the Ethernet is connected
to a switch, a crossover cable is
required.
Apply short reset or long reset.
Repair or replace faulty equipment.
Solution
It is strongly recommended to manually
configure all devices to matching speed
and duplex settings. If manual settings are
not available, both devices must be set to
auto-negotiate.
If the AN-80i is connected to a host
computer or server operating at 10Base-T,
this is normal operation.