Where DFS is required by regional regulations, this function is permanently enabled
7.
at the factory and can not be disabled by the installer or end-user. Refer to section
7.7: Regional Codes for additional information.
1.5.2

Installation and Operation

FCC Part 90 guidelines for deployment of AN-80i systems in the frequency band of
3650-3700 MHz for "restricted" CBP (Contention Based Protocol) in USA includes
restrictions on the maximum EIRP.
To comply with these guidelines, the following EIRP limitations are applied for
deployment in this band:
i) Max EIRP of 25 Watts/25 MHz (equivalent to 1 Watt/1 MHz)
ii) Peak EIRP Power Density of 1 Watt in any 1 MHz slice of spectrum.
To ensure compliance with these restrictions, refer to the following important notices:
1.
The 3650-3700 MHz frequency range is a licensed band in the USA and operators
must have a valid spectrum license to operate AN-80i equipment using this band.
2.
The AN-80i requires a Redline FCC-specific options key that is mandatory for
operation within the USA. This options key enforces the FCC approved operating
range of 3650-3700 MHz.
3.
The AN-80i outdoor transceiver and antenna must be professionally installed.
4.
Changes or modifications not expressly approved by Redline Communications could
void the user's authority to operate the equipment.
5.
Do not operate an AN-80i outdoor transceiver until you have confirmed the FCC-
specific options key is loaded and active (operating range restricted to 3650-3700
MHz). When the FCC-specific options key is installed, the operator is not able to set
an RF frequency that exceeds the allowed range of 3650-3700 MHz.
6.
The AN-80i transmit power settings must not exceed values stated in the AN-80i
User Manual.
1.5.3

FCC Power Settings

FCC regulation part 90.1321 (governing operation in the 3650-3700 MHz band in the
US) states that base station transmissions are limited to a maximum transmit power of 1
Watt/MHz (peak EIRP). Refer to the section on FCC antennas at the end of this manual..
1.6

UL Information

The suitability of the supplied Ethernet cable is subject to the approval of Authority
1.
Having Jurisdiction and must comply with the local electrical code.
The equipment must be properly grounded according with NEC and other local
2.
safety code and building code requirements
To meet the over-voltage safety requirements on the telecommunications cables, a
3.
minimum 26 AWG telecommunication line cord must be used.
"Pour être en conformance avec les exigences finies de sûreté de sur-tension sur les
4.
câbles de télécommunications un fil de télécommunication ayant un calibre minimum
de 26 AWG doit être utilisé."
Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC
5.
which provides guidelines for proper grounding and, in particular, specifies that the
cable ground shall be connected to the grounding system of the building, as close to
the point of cable entry as is practical.