Deployment In The Usa -- Fcc Notices; Fcc & Ic Notice; Table 1: Fcc & Ic Rf Recommended Safe Separation Distances - Redline RedCONNEX RedACCESS AN-80IE User Manual

Table of Contents

Advertisement

If you have determined that it is appropriate to install lightning protection for your system,
the following general industry practices are provided as a guideline only:
The AC wall outlet ground for the indoor POE adapter should be connected to the
1.
building grounding system.
Install a lightning arrestor in series with the Ethernet cable at the point of entry to the
2.
building. The grounding wire should be connected to the same termination point
used for the tower or mast.
Install a lightning arrestor in series with the Ethernet cable as close to the AN-80i as
3.
practical. The grounding wire should be connected to the same termination point
used for the tower or mast.
Provide direct grounding from the AN-80i, the mounting bracket, the antenna, and
4.
the Ethernet cable surge protection to the same ground bus on the building. Use the
grounding screws provided for terminating the ground wires.
1.5

Deployment in the USA -- FCC Notices

1.5.1
FCC & IC Notice
The Model AN-80i and its antenna must be professionally installed.
1.
WARNING -- FCC & IC RF Exposure Warnings
2.
To satisfy FCC and IC RF exposure requirements for RF transmitting devices, the
following distances should be maintained between the antenna of this device and
persons during device operation:
Table 1: FCC & IC RF Recommended Safe Separation Distances
Frequency (GHz)
3.650 - 3.675
3.3 - 3.8
4.9 - 5.3
To ensure compliance, operation at closer than these distances is not
recommended. The antenna used for this transmitter must not be collocated in
conjunction with any other antenna or transmitter.
High power radars are allocated as primary users (meaning they have priority) of
3.
5250-5350 MHz and 5650-5850 MHz and these radars could cause interference
and/or damage to LE-LAN devices.
FCC Information to Users @ FCC 15.21 & 15.105:
4.
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Warning: Changes
5.
Communications could void the user's authority to operate the equipment.
Refer to section 7.6: FCC & IC Certified Antennas for additional information.
6.
70-00072-01-07
5.4
5.8
or
modifications
Proprietary Redline Communications © 2008
&
AN-80i
Mode
PTP / PMP
PTP / PMP
PTP / PMP
PTP / PMP
PMP
PTP
not
expressly
User
Manual
Separation Distance
130 cm (52 in) or more
130 cm (52 in) or more
255 cm (101 in) or more
40 cm (16 in) or more
20 cm (8 in) or more
310 cm (122 in) or more
approved
by
Redline
Page 11 of 106
Sept 18, 2008