(2) Detaching and refitting the main charger unit

Follow the procedure below to replace the main charger unit.
Procedure
1. Open the front cover.
2. Pull the main charger unit.
3. While pressing the lock lever and remove
the main charger unit.
4. Replace the main charger unit and install
the unit.
The main charger unit, when fully inserted,
must be set aside towards the drum unit.
Front cover
Figure 1-5-68
Drum unit
Main charger unit
Main charger unit
Figure 1-5-69
2H0/2HZ