(14) Offset occurs.

Copy example
Defective cleaning blade.
Defective fuser unit.
Wrong types of paper.

(15) Image is partly missing.

Copy example
Paper damp.
Paper creased.
Drum condensation.
Dirty or flawed drum.

(16) Fusing is poor.

Copy example
Wrong types of paper.
Defective pressure springs.
Flawed press roller.
Flawed fuser heater.

(17) Image is out of focus.

Copy example
Defective image scanning unit.
Drum condensation.
Causes
Replace the drum unit (see page 1-5-35).
Check the heat roller and press roller.
Check if the paper meets specifications. Replace paper.
Causes
Check the paper storage conditions.
Change the paper.
Perform the drum refresh operation.
Perform the drum refresh operation. If the drum is flawed,
replace the drum unit (see page 1-5-35).
Causes
Check if the paper meets specifications. Replace paper.
Replace the pressure springs.
Replace the press roller (see page 1-5-45).
Replace the fuser heaters (see page 1-5-47).
Causes
Replace the image scanning unit (see page 1-5-19).
Perform the drum refresh operation.
Check procedures/corrective measures
Check procedures/corrective measures
Check procedures/corrective measures
Check procedures/corrective measures
2H0/2HZ-1