item No.
Adjusting margins for scanning an original on the platen
U403
Description
Adjusts margins for scanning the original on the platen.
Purpose
Make the adjustment if margins are incorrect.
Adjustment
1. Press the start key.
2. Select the item to be adjusted.
Display
A MARGIN
B MARGIN
C MARGIN
D MARGIN
3. Press the system menu key.
4. Place an original and press the start key to make a test copy.
5. Press the system menu key.
6. Change the setting value using the +/- keys.
Increasing the value makes the margin wider, and decreasing it makes the margin narrower.
7. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U403
Completion
Press the stop key. The indication for selecting a maintenance item No. appears.
Description
Description
Scanner left margin
Scanner leading edge margin
Scanner right margin
Scanner trailing edge margin
Scanner leading edge margin
(3±1.5 mm)
Scanner
left margin
(2±1.0 mm)
Scanner trailing edge margin
(2±1.0 mm)
Figure 1-3-19
U404
(P.1-3-66)
Setting
Initial
Change in
range
setting
value per step
0 to 10.0
2.0
0.5 mm
0 to 10.0
2.0
0.5 mm
0 to 10.0
2.0
0.5 mm
0 to 10.0
2.0
0.5 mm
Scanner
right margin
(2±1.0 mm)
2H0/2HZ