Maintenance
item No.
Checking solenoid operation
U033
Description
Applies current to each solenoid in order to check its ON status.
Purpose
To check the operation of each solenoid.
Method
1. Press the start key.
2. Select the solenoid to be operated.
3. Press the start key. The solenoid turns on for 1 s.
Display
BRANCH1
BRANCH2
MOTOR ON
*Optional.
To stop motor driving, press [MOTOR ON] again.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Solenoids
Feedshift solenoid (FSSOL)
Feedshift solenoid (FSSOL)*
The main motor (MM) and the paper feed motor (PFM) are
turned on.
2H0/2HZ