Kyocera Mita KM-2560 Service Manual page 206

Hide thumbs Also See for Mita KM-2560:
Table of Contents

Advertisement

2H0/2HZ
4. Insert the locating ball on each of the scan-
ner wires into the hole in the respective
scanner wire drum and wind the scanner
wire three turns inward and four turns out-
ward.
With the locating ball as the reference point,
wind the shorter end of each of the wires
outward.
5. Secure the scanner wires using the scanner
wire stoppers.
6. Refit the scanner wire drum shaft to the
scanner unit.
7. Insert the two frame securing tools into the
positioning holes at the front and rear of the
scanner unit to fix the mirror 2 frame in posi-
tion.
1-5-26
Scanner wire stoppers
Three turns
inward
Locating
ball
Four turns
outward
Scanner wire drum
Figure 1-5-47
Frame securing tool
Three turns
inward
Four turns
outward
Frame securing tool
Mirror 2 frame
Figure 1-5-48