Connector
Pin No.
YC18
21
GND
Connected
22
CPN
to the CCD
23
N.C.
PWB
24
10V
YC19
A1
+5V1
Connected
A2
GND
to the
A3
AFESEL
engine PWB
A4
AFERDY
A5
AFESI
A6
AFESCLKN
A7
AFESDO
A8
E2CSDIR
A9
E2CSBSY
A10
E2CEGSI
A11
E2CSCKN
A12
E2CEGSO
A13
SLEEP
A14
24VDN
A15
OPSWN
B1
OVSYNC
B2
SCANHLDN
B3
EGSCANRDY
B4
GND
B5
OUTPEN
B6
GND
B7
E2CEGIRN
B8
GND
B9
EGHLDN
B10
GND
B11
EGRESETN
B12
GND
B13
PDMASKN
B14
GND
B15
+3.3V_EGN
YC21
1
PDN
Connected
2
SGND
to the LSU
3
OUTPEN
4
SAMPLEN
5
VDOP
6
VDON
7
+5V1
Signal
I/O
Voltage
-
-
O
0/3.3 V DC
-
-
O
10 V DC
I
5 V DC
-
-
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC (pulse) Serial communication data signal
O
0/3.3 V DC (pulse) Clock signal
I
0/3.3 V DC (pulse) Serial communication data signal
I
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Serial communication data signal
O
0/3.3 V DC (pulse) Clock signal
I
0/3.3 V DC (pulse) Serial communication data signal
O
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
I
0/3.3 V DC
-
-
I
0/3.3 V DC
-
-
O
0/3.3 V DC
-
-
O
0/3.3 V DC
-
-
I
0/3.3 V DC
-
-
I
3.3 V DC
I
0/3.3 V DC
-
-
O
0/3.3 V DC
O
0/3.3 V DC
O
-
O
-
O
5 V DC
Description
Ground
CCD control signal
Not used
10 V DC power output to CCDPWB
5 V DC power input from EPWB
Ground
Select signal
Ready signal
E2CSDIR signal
E2CSBSY signal
Sleep signal: On/Off
24 V DC power shut-off signal
Not used
Original scanning interval signal
Scanner hold signal
Printing image interval signal
Ground
Laser diode output signal
Ground
E2CEGIRN signal
Ground
Engine hold signal
Ground
Reset signal
Ground
Auxiliary scanning interval signal
Ground
3.3 V DC power input from EPWB
Laser sync signal
Ground
Laser diode output signal
Sample hold signal
Image data signal
Image data signal
5 V DC power output to APCPWB