Kyocera Mita KM-2560 Service Manual page 197

Hide thumbs Also See for Mita KM-2560:
Table of Contents

Advertisement

9. Remove the connector of the scanner
inverter PWB.
10. Release the clamp and remove the wire.
11. Pull the connector out from the opening on
the rear of the scanner unit.
12. Remove two films.
13. Remove the wire guide lid.
14. Move the mirror 1 frame to notch position.
Scanner inverter PWB
Opening
Figure 1-5-31
Film
Mirror 1 frame
Notch position
Figure 1-5-32
2H0/2HZ
Connector
Clamp
Film
Notch position
Wire guide lid
1-5-17