Kyocera Mita KM-2560 Service Manual page 275

Hide thumbs Also See for Mita KM-2560:
Table of Contents

Advertisement

Connector
Pin No.
YC1
A1
GND
Connected
A2
TONEFUL
to the over-
A3
+5V
flow sensor,
A4
+24V
cleaning
lamp, toner
A5
ERASE3N
sensor,
A6
ERASE2N
humidity
A7
ERASE1N
sensor,
toner feed
A8
GND
motor,
A9
DEVDETN
developing
A10
+5V
PWB, drum
PWB and
A11
+5V
fuser unit
A12
HUMID_SDA
A13
GND
A14
HUMID_SCL
A15
TNMOT24V
A16
TNMOTREM
B1
IUID1DETN
B2
GND
B3
IUID1SDA
B4
IUID1SCL
B5
+5V
B6
IUID2DETN
B7
GND
B8
IUID2SDA
B9
IUID2SCL
B10
+5V
B11
THEAMA_GND
B12
THEAMA
B13
FUFMLTN
B14
FIXTHCEN
B15
N.C.
B16
+3.3V
YC2
1
+24VSL
Connected
2
GND
to the poly-
3
PLGDRN
gon motor,
4
PLGRDYN
cooling fan
motor 1,
5
PLGCLKN
toner con-
6
FAN1 DRN
tainer sen-
7
FAN1 POW
sor and
toner con-
8
GND
tainer detec-
9
COUNTSENS
tion switch
10
+5VSL
15
CONTSW
16
GND
Signal
I/O
Voltage
-
-
I
0/5 V DC
O
5 V DC
O
24 V DC
O
0/24 V DC
O
0/24 V DC
O
0/24 V DC
-
-
I
0/5 V DC
O
5 V DC
O
5 V DC
I/O
Analog
-
-
O
0/5 V DC (pulse)
O
24 V DC
O
0/24 V DC
I
0/5 V DC
-
-
I/O
0/5 V DC (pulse)
O
0/5 V DC (pulse)
O
5 V DC
I
0/5 V DC
-
-
I/O
0/5 V DC (pulse)
O
0/5 V DC (pulse)
O
5 V DC
-
-
I
Analog
O
0/5 V DC
I
Analog
-
-
O
3.3 V DC
O
24 V DC
-
-
O
0/24 V DC
I
0/5 V DC
O
0/5 V DC (pulse)
O
0/24 V DC
O
24 V DC
-
-
I
0/5 V DC
O
5 V DC
I
0/5 V DC
-
-
Description
Ground
OFS: On/Off
5 V DC power output to OFS
24 V DC power output to CL
CL: On/Off
CL: On/Off
CL: On/Off
Ground
TNS: On/Off
5 V DC power output to TNS
5 V DC power output to HUMS
HUMS detection voltage signal
Ground
HUMS clock signal
24 V DC power output to TFM
TFM: On/Off
Developing unit detection signal
Ground
Developing unit EEPROM data signal
Developing unit EEPROM clock signal
5 V DC power output to developing unit
Drum unit detection signal
Ground
Drum unit EEPROM data signal
Drum unit EEPROM clock signal
5 V DC power output to drum unit
Ground
FTH1 detection voltage signal
Fuse cut signal
FTH2 detection voltage signal
Not used
3.3 V DC power output to FUPWB
24 V DC power output to PM
Ground
PM: On/Off
PM ready signal
PM clock signal
CFM1: On/Off
24 V DC power output to CFM1
Ground
TCS: On/Off
5 V DC power output to TCS
TCDSW: On/Off
Ground
2H0/2HZ
2-3-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mita km-30601102h03nl0

Table of Contents