2H0/2HZ
Maintenance
item No.
Setting the other high voltages
U101
Description
Sets the developing bias control voltage, the transfer control voltage and the separation control voltage or
checks the output of these voltages. Sets the transfer control voltage and the separation control voltage ON/
OFF timing.
Purpose
To check the developing bias, the transfer voltage and the separation voltage or to take measures against
drop of image density or background fog.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting using the +/- keys.
Display
DEV BIAS
DEV SBIAS
DEV DUTY
TC DATA
SC DATA
TC DATA2
TC ON
TC OFF
SC ON
SC OFF
Increasing the DEV BIAS setting makes the image darker; decreasing it makes the image lighter.
Increasing the DEV SBIAS setting makes the image darker.
Increasing the DEV DUTY setting makes the image lighter; decreasing it makes the image darker.
Increasing the TC DATA/TC DATA2 setting makes the transfer voltage higher, and decreasing it makes
the voltage lower.
Increasing the SC DATA setting makes the separation voltage higher, and decreasing it makes the volt-
age lower.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Checking the drum count
U110
Description
Displays the drum counts for checking.
Purpose
To check the drum status.
Method
Press the start key. The drum counter count is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-42
Description
Description
Developing bias AC component frequency at image
formation
Developing shift bias potential at image formation
Developing bias AC component duty at image forma-
tion
Transfer control voltage
Separation control voltage
Transfer control voltage for small sizes
Time of period since the registration clutch is turned
on until the transfer voltage is turned on
Time of period since the registration clutch is turned
off until the transfer voltage is turned off
Time of period since the registration clutch is turned
on until the separation voltage is turned on
Time of period since the registration clutch is turned
off until the separation voltage is turned off
Setting
Initial
range
setting
20 to 32
26
0 to 255
58
0 to 100
50
0 to 255
89
0 to 2
1
0 to 255
115
0 to 255
91
0 to 255
68
0 to 255
40
0 to 255
92