Maintenance
item No.
Setting detection sensor threshold value
U099
1. Select an item to be set.
2. Adjust the setting using the +/- or numeric keys.
Display
ORIGINAL R
ORIGINAL G
ORIGINAL B
LIGHT SOURCE R Light source threshold value (R)
LIGHT SOURCE G Light source threshold value (G)
LIGHT SOURCE B Light source threshold value (B)
WAIT TIME
A4R AREA
3. Press the start key. The value is set.
4. To return to the screen for selecting an item, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting the main high voltage
U100
Description
Performs main charging.
Purpose
To check main charging.
Method
1. Press the start key.
2. Select the item to be operated.
3. Press the start key. The selected operation starts.
Display
MC ON
LASER ON/OFF
4. To stop operation, press the stop key.
Completion
Press the stop key when main charger output stops. The screen for selecting a maintenance item No. is dis-
played.
Description
Description
Original threshold value (R)
Original threshold value (G)
Original threshold value (B)
Time from activation of the original detection switch
(ODSW) to original size judgment
Original size detection position display (mm)
Description
Turning the main charger on
Turning the main charger on and the laser scanner unit on and off
2H0/2HZ
Setting
Initial
range
setting
0 to 255
105
0 to 255
105
0 to 255
105
0 to 255
60
0 to 255
60
0 to 255
60
0 to 255
150
220/240
240
1-3-41