Furuno FAR-2228 Installation Manual page 79

Hide thumbs Also See for FAR-2228:
Table of Contents

Advertisement

7) Fasten the base of the heater as shown in the following figure, using the sup-
plied installation materials.
M5 screw
M5 screw
8) Attach the supplied earth label over the earth label currently attached near the
grounding terminal.
8. Position the cables so their armors lie beneath their respective cable clamps in the
cable entrance. Fasten the cable clamps.
9. Coat the hinge with the supplied adhesive for hinge waterproof then close the ca-
ble entrance cover. Fix the cable cover with four screws, then coat the screws with
the supplied adhesive.
Adhesive
10. Reconnect the performance monitor connector (J807) to the RF-TB Board.
M5 screw
M5 screw
Fixing
Fixing
shaft
shaft
Grounding
Grounding
terminal
terminal
Cable clamp
Close
Cable entrance cover
2. WIRING
Cover bolt
Cover bolt
Earth label
Screw
Adhesive