2. WIRING
3. Connect the lines of the cable for Processor Unit as shown below through the wir-
ing clamp (B).
• Serial lines: TB704
• Shield line: Screw (A)
• LAN cable: J503
Connection of cable for Control Unit
1. Connect the lines of the cable to the appropriate WAGO connectors (TB711 and
TB712), referring to the interconnection diagram at the back of this manual.
2. Set the heat shrinkable part of the cable for Control Unit on the appropriate lane
on the lower cable entrance, as shown below. Fasten the copper part of the cable
with the cable clamp.
2-52
Cable for Control Unit
(B)
(A)
J503 (LAN cable)
Cable for Processor Unit
Set the heat
shrinkable tube
on the lane.
TB704
Clamp the
copper part.