14.9
Automation setup for Dolby devices
The SX-3000 server supports automation for the Dolby sound processors. Follow the steps
below to configure a Dolby device in the server automation interface.
1. Click the [Add] button on the [Devices] tab and enter the name of the device. In this
case, it is "CP650". Set the device type to "DolbyCP650".
2. Click [OK] and set up the device parameters for the Dolby CP650 device.
3. Enter the IP address of the Dolby CP650 device (see Figure 61).
4. Default Control cues are set up for a new Dolby CP650 automation device. Control cues
can be added or removed using the [+] and [-] buttons.
5. Click the [Save] button to save configured settings.
SX-3000 Installation Manual
Figure 60 Dolby CP650 automation device setup
Figure 61 Automation settings for Dolby CP650 device
Page 38 of 43