12.4.

CONTROL BOARD

12.4.1 Safety Precautions
Ensure the power is completely disconnected from the scanner unit.
Ensure the scanner is positioned on a stable maintenance platform.
Employ static safety precautions when handling electronic boards and integrated circuits.
12.4.2 Tools
Medium pozi-drive screwdriver.
Small pozi-drive screwdriver.
12.4.3 Associated Part Numbers
P003320 Control Board
P003302 Control Board Bracket
12.4.4 Procedures
1. Remove the Lid Cover
Extrusion Sub-A as in
Chapter 11.3.
2. Remove the M3 Pan Head
screws from the Control
board bracket.
3. Lift and rotate the control
board bracket upside down
and disconnect all the
cables. As the 4
connectors look identical
on the left hand side, it is
worth marking their
positions to ensure they
are positioned correctly
during reassembly.