17.3.

DIAGNOSTIC - NETWORK CONNECTION

Ethernet Check List For Colortrac Scanner (using the menu button on the control panel).
Enter your company issued IP address into the scanner.
Enter the Data Port address. (Recommended value of "17237", unless company IT department
uses a different value).
Enter Command Port address. (Recommended value of "17236", unless company IT department
uses a different value).
Make sure the MAC address gives a unique address. (If reads only 'FF's, please contact
support@colortrac.com).
Ethernet Check List for Colortrac Software.
Install the Ethernet driver, latest version on the company website
(http://www.colortrac.com/support/support_downloads.htm).
Enter the same company issued IP address as in the scanner.
Enter the Data port value as entered in the scanner. (See table below for data info)
Enter the Command port value as entered in the scanner. (See table below for data info)
After entering all the information, shut down and re-open the software.
Make sure the software Ethernet settings are entered in all the Colortrac software/utilities in the same
way. Refer to the user manual for reference to using the software/utilities
For further Ethernet diagnostics, follow the chart on the following pages.
Port Settings
Recommended Value
17236
(or same as scanner)
17237
(or same as scanner)
ScanWorks / Utilities
Command Port
Data Port
Ci Scanner Service Manual
SmartLF all in one
Port 2
Port 1
CopySmart
Port 1
Port 2