Alphanumeric Display

During the test cycle, the 32-character, single line alphanumeric display will provide data in four
segments: CONDITION, FROM POINT, TO POINT, and CIRCUIT LABELS. All four
segments use upper case alphanumeric characters. Within the CONDITION segment, any of the
readouts shown in the Table below will appear:
CONDITION
FROM POINT
O
JA-1
READOUT
Passed
(1-4096)
OK
OK
OK
ERROR
"O"
"S"
"F"
"T"
TO POINT
JB-56
INTERPRETATION
A successful test condition.
Number of points successfully passed in Self Test.
Successful completion of Learn Know Good.
Completion of Sequential Build
Completion of Print Error List or Print Wire List.
Failure of a test, at the end of the test.
An "open" failure.
A "short" failure.
Body Conductance is present on the displayed From point number
Body Conductance is present on the Displayed To point number.
CIRCUIT LABEL
RED/WHITE