Cablescan 4000C Instruction Manual page 72

Continuity tester
Table of Contents

Advertisement

Model 4000C Instruction Manual
To correct an error, follow the procedure below:
1. If the Replace mode is selected with an RU in the left column, press ESC once to select
the Cursor Positioning mode. (Pressing ESC again, from the Cursor Positioning mode,
exits the editor.)
2. Using the Up/Down arrows, scroll to the point number that contains the error.
3. Select the Replace mode by typing R, and pressing ENTER.
4. Type the correct label.
Before the cursor can be moved, the editor must be in the cursor positioning mode denoted by
only a U displayed in the left column. The cursor can be moved two ways: using the arrow keys
and using the Find command. The cursor can be moved to the desired location using the Up and
Down arrows while only a U is displayed in the left column. To move the cursor with the Find
command follow the procedure below:
1. If RU or AU is displayed in the left column, press ESC. A U will display in the left
column.
2. Press F followed by a SPACE.
1. To find a point number, type the point number, and press ENTER. The cursor will be
placed on the line containing the point number. (The point number can be above the
cursor position.)
2. To move to the top of the table (point number 1) type F 1 followed by an ENTER.
1. User labels are searched beginning at the cursor and searching down. If a label is above
the cursor, or you are not sure, move to the top of the table by finding point number one.
Type F 1 followed by an ENTER.
2. To find a user label, type the label, and press ENTER.
CORRECTING A USER NOTATION ERROR
MOVING THE CURSOR IN THE USER LIST
Finding a Point Number
Finding a User Label