12. Type each of the remaining eight circuits from the wire list document. After all circuits
have been entered, the screen should display the following:
W
0001
R
W
0001
RW 0001
R
RW 0002
R
RW 0003
R
RW 0004
R
RW 0005
R
RW 0006
R
RW 0007
R
RW 0008
R
RW 0009
R
RW 00010
To correct an error, follow the procedure below:
1. If the replace mode is selected with an RW in the left column, press ESC once to select
the Cursor Positioning mode. (Pressing ESC again from the Cursor Positioning mode
exits the editor.)
2. Using the Up or Down arrow, scroll to the line or sequence containing the error. (Refer
to Moving the Cursor in the Wire List, below.)
3. Select the Replace mode by typing R, and pressing ENTER.
4. The data currently programmed for the sequence will be displayed above the cursor line.
The cursor will be placed on the From point. The cursor will move to the next field, To
Point, then Wire Label, each time ENTER is pressed. Position the cursor to the field
error and retype the correct data.
P3-4
P1-A
WS01
P3-2
P1-B
WS02
P3-3
P1-C
WS03
P3-1
P1-D
WS04
E1
P1-E
WS05
E2
P1-F
WS06
P2-2
P1-H
WS07
P2-1
P1-J
WS08
P2-3
P1-K
WS09
P2-4
P1-L
WS10
CORRECTING A WIRE LIST ERROR