Cablescan 4000C Instruction Manual page 74

Continuity tester
Table of Contents

Advertisement

Model 4000C Instruction Manual
5. Wire continuities are typically entered while in the Replace mode. (The Add mode is
used only to insert wire continuities between lines.) To select the Replace mode, type R
and press ENTER. While in the Replace mode, the screen should display RW to the left
of each new line as it is displayed, as shown below:
 ED
EDIT (W, U)
EDIT Wire List
W
0001
I
Initialize? Y
W
0001
R
W
RW 0001
Two lines are displayed while in the Replace mode each time a new
circuit or wire is entered. The first line, with only a W to the left, is the
data already entered for that sequence (line). With no data entered, the
line will be blank as shown above.
6. The wire list document for the wire harness will be used for entering the From/To list.
Enter P3-4, the first termination point in the Wire List and press ENTER.
For build applications, the line order of the From/To list determines the
sequential build order. The list should be entered in the proper order
for the application.
7. Type P1-A, the To point termination of the first circuit in the wire list, and press ENTER.
8. The third column is for the wire or circuit label; it can contain information regarding the
circuit or wire up to 12 characters. For this example, the wire number will be used for
added information. For other applications, the wire color and gauge may be used. Type
WS01, and press ENTER.
9. Type the From point, P3-2, for the second wire, and press ENTER.
10. Type the To point, P1-B, for the second wire, and press ENTER.
11. Type WS02, the wire label for circuit 2, and press ENTER.
NOTE