Section 7
Current protection
No.
StartMode
21
LatchedStart
22
FollowStart
23
FollowStart
24
FollowStart
25
FollowStart&
Mode
26
FollowStart&
Mode
27
FollowStart&
Mode
190
RetripMode
t1 and t2
initiated with
Always
external START
Off
external START
UseFunction
external START
Mode
Always
external START
Off
external START
and current
above set level
UseFunction
external START
Mode
and current
above set level
Always
external START
and current
above set level
When t1 has
When t2 has
elapsed, TRRET will
elapsed, TRBU will
be given if
always be given
current is above set
level of IPh> and
higher than
I>BlkCBPos or
CBCLD input has
logical value one
when current is
smaller than
I>BlkCBPos
never be given
current is above set
level of IPh> and
higher than
I>BlkCBPos or
CBCLD input has
logical value one
when current is
smaller than
I>BlkCBPos
be given if current
current is above set
is above set level
level of IPh> and
of IPh> and higher
higher than
than I>BlkCBPos
I>BlkCBPos or
or CBCLD input
CBCLD input has
has logical value
logical value one
one when current
when current is
is smaller than
smaller than
I>BlkCBPos
I>BlkCBPos
be given if
current is above set
external START is
level of IPh> and
present
higher than
I>BlkCBPos or
CBCLD input has
logical value one
when current is
smaller than
I>BlkCBPos
never be given
current is above set
level of IPh> and
higher than
I>BlkCBPos or
CBCLD input has
logical value one
when current is
smaller than
I>BlkCBPos
be given if current
current is above set
is above set level
level of IPh> and
of IPh> and higher
higher than
than I>BlkCBPos
I>BlkCBPos or
or CBCLD input
CBCLD input has
has logical value
logical value one
one when current
when current is
is smaller than
smaller than
I>BlkCBPos
I>BlkCBPos
be given if
current is above set
external START is
level of IPh> and
present
higher than
I>BlkCBPos or
CBCLD input has
logical value one
when current is
smaller than
I>BlkCBPos
1MRK 505 370-UEN D
t1 and t2 will be
stopped
(reset) if
t1 and (t2 or t2MPh)
and 150ms expires
and current is below
set level of IPh> or
CBCLD input has
logical value zero
external START
disappears
external START
disappears
external START
disappears
current is below set
level of IPh> or
external START
disappears
current is below set
level of IPh> or
external START
disappears
current is below set
level of IPh> or
external START
disappears
Busbar protection REB670
Application manual