1MRK 505 370-UEN D
No.
StartMode
12
LatchedStart
13
FollowStart
14
FollowStart
15
FollowStart
16
FollowStart&
Mode
17
FollowStart&
Mode
18
FollowStart&
Mode
No.
StartMode
FunctionMode = Current or CB Pos
19
LatchedStart
20
LatchedStart
Table continues on next page
Busbar protection REB670
Application manual
RetripMode
t1 and t2
initiated with
Always
external START
Off
external START
UseFunction
external START
Mode
Always
external START
Off
external START
and CBCLD
input has
logical value
one
UseFunction
external START
Mode
and CBCLD
input has
logical value
one
Always
external START
and CBCLD
input has
logical value
one
RetripMode
t1 and t2
initiated with
Off
external START
UseFunction
external START
Mode
When t1 has
When t2 has
elapsed, TRRET will
elapsed, TRBU will
be given if
always be given
CBCLD input has
logical value one
never be given
CBCLD input has
logical value one
be given if CBCLD
CBCLD input has
input has logical
logical value one
value one
if external START
CBCLD input has
is present
logical value one
never be given
be given if CBCLD
input has logical
value one and
external START is
present
be given if CBCLD
be given if CBCLD
input has logical
input has logical
value one and
value one and
external START is
external START is
present
present
be given if
be given if CBCLD
external START is
input has logical
present
value one and
external START is
present
When t1 has
When t2 has
elapsed, TRRET will
elapsed, TRBU will
be given if
never be given
current is above set
level of IPh> and
higher than
I>BlkCBPos or
CBCLD input has
logical value one
when current is
smaller than
I>BlkCBPos
be given if current
current is above set
is above set level
level of IPh> and
of IPh> and higher
higher than
than I>BlkCBPos
I>BlkCBPos or
or CBCLD input
CBCLD input has
has logical value
logical value one
one when current
when current is
is smaller than
smaller than
I>BlkCBPos
I>BlkCBPos
Section 7
Current protection
t1 and t2 will be
stopped
(reset) if
t1 and (t2 or t2MPh)
and 150ms expires
and CBCLD input
has logical value
zero
external START
disappears
external START
disappears
external START
disappears
CBCLD input has
logical value zero or
external START
disappears
CBCLD input has
logical value zero or
external START
disappears
CBCLD input has
logical value zero or
external START
disappears
t1 and t2 will be
stopped
(reset) if
t1 and (t2 or t2MPh)
and 150ms expires
and current is below
set level of IPh> or
CBCLD input has
logical value zero
t1 and (t2 or t2MPh)
and 150ms expires
and current is below
set level of IPh> or
CBCLD input has
logical value zero