Connectors, If Side Of M1740A Mmwave Transceiver - Keysight Technologies S9100A Startup Manual

5g multi-band vector transceiver
Table of Contents

Advertisement

3. 2. 7. 3 Connectors, IF Side of M1740A mmWave Transceiver
S9100A 5G Multi-Band Vector Transceiver, Startup Guide
LO/IF Out
Connector
IF In/Out
Connector
IF frequency range
IF input power range
IF output power range
IF In
Connector
IF frequency range
IF input power range
LO/Pwr/Ctrl/IF In
Connector
Frequency range,
LO,
DC power
Do not connect or disconnect the RF cable, at either end, while
the connected instrument is powered on.
3 Review Hardware Components
SMA (f), 50 Ω, nominal
This port provides the IF output of the down-
converter in the M1740A. This port also accepts an
LO input to be used by the downconverter.
SMA (f), 50 Ω, nominal
This port can be used either to accept an IF input to
the upconverter in the M1740A or to provide the IF
output of the downconverter in the M1740A.
2.5 to 4 GHz
–20 to –30 dBm minimum, CW
–24 to –8 dBm, CW
SMA (f), 50 Ω, nominal
This port accepts an IF input to the upconverter in
the M1740A.
2.5 to 4 GHz
–20 to –30 dBm minimum, CW
SMA (f), 50 Ω, nominal
This port accepts an IF input to the upconverter in
the M1740A. This port also accepts the following
inputs, which are combined with the IF input signal:
An LO input to be used by the upconverter
and/or downconverter in the M1740A.
A +36 VDC voltage input to power the
M1740A.
A control signal to operate the M1740A.
6 to 12 GHz,
–20 dBm, minimum
+36 VDC, 1A
35

Advertisement

Table of Contents
loading