Environmental Conditions (Operating) - Keysight Technologies S9100A Startup Manual

5g multi-band vector transceiver
Table of Contents

Advertisement

2 Review Safety Requirements

2. 6 Environmental Conditions (Operating)

The Keysight S9100A 5G Multi-Band Vector Transceiver is designed for use in the
following conditions:
For indoor use only
Altitude up to 6,561.68 ft (2,000 m)
Operating Temperature 10 to 40° C,
5% to 85% (non-condensing) relative humidity.
Samples of these products have been type tested in accordance with the Keysight
Environmental Test Manual and verified to be robust against the environmental
stresses of Storage, Transportation and end-use. Those stresses include, but are not
limited to temperature, humidity, shock, vibration, altitude and power line conditions.
Test Methods are aligned with IEC 60068-2 and levels are similar
to MIL-PRF-28800F Class 3.
8
The Keysight S9100A Base System and the E7770A CIU are
designed for use in Installation Category II and Pollution Degree 2,
per IEC 61010 Second Edition and 664 respectively.
The M1740A mmWave Transceiver is designed for use in
Installation Category II and Pollution Degree 2, per IEC 61010-1
Third Edition and 664 respectively.
S9100A 5G Multi-Band Vector Transceiver, Startup Guide