5-9-7. Reel Table Rotation Sensor Position Adjustment

5-9-7. Reel Table Rotation Sensor Position Adjustment
Note
. Be sure to check the position of the reel table rotation sensor when a reel motor
assembly or reel table is replaced.
Tools
. Thickness gauge:
9-911-053-00
. Torque screwdriver (6 k.cm) (JB-5251): J-6252-510-A
. Betacam cassette tape
Check
1. Check the Reel Table Rotation Sensor
Clearance
Reel table
Reel table rotation sensor
Check that the clearance between the reel table
and the reel table rotation sensor satisfies the
specification 1.
If the specification 1 is not satisfied, perform
steps 4 and later.
A
Spec.1 : A = 0.1 mm or more
Check the Reel Table Rotation Sensor Clearance