3-8. Analog Betacam PB System Alignment
3-8-1. Adjustment Overview
Adjustment Items
No.
Item
3-8-3
Initial data setting
3-8-4
EQ RF output level adjustment
3-8-5
Cosine equalizer adjustment
OMC DC offset
METAL Y
METAL C
OXIDE C
OXIDE Y
Data save
3-8-6
Cosine equalizer provisional adjustment
OMC: Over-Modulation Compensation circuit
*1: RV103 is not equipped on the DM-89 board of LOT Nos. 407 and higher.
3-50
Adjustment point
All data of A3 : BETACAM PB ADJUST
METAL Y
A30 : EQ VR : RF GAIN METAL-Y-A
A30 : EQ VR : RF GAIN METAL-Y-B
METAL C
A30 : EQ VR : RF GAIN METAL-C-A
A30 : EQ VR : RF GAIN METAL-C-B
OXIDE C
A30 : EQ VR : RF GAIN OXIDE-C-A
A30 : EQ VR : RF GAIN OXIDE-C-B
OXIDE Y
A30 : EQ VR : RF GAIN OXIDE-Y-A
A30 : EQ VR : RF GAIN OXIDE-Y-B
Data save
A3F : NV-RAM CONTROL
A35 : DM VR 4 : OMC DC METAL-Y
A35 : DM VR 4 : OMC DC METAL-C
A35 : DM VR 4 : OMC DC OXIDE-Y
A35 : DM VR 4 : OMC DC OXIDE-C
Group delay
1RV101/DM-89, 1RV102/DM-89
Main
A33 : DM VR 2 : MAIN METAL-Y-A
A33 : DM VR 2 : MAIN METAL-Y-B
Sub
A34 : DM VR 3 : SUB METAL-Y-A
A34 : DM VR 3 : SUB METAL-Y-B
1RV301/DM-89, 1RV302/DM-89
Group delay
Main
A33 : DM VR 2 : MAIN METAL-C-A
A33 : DM VR 2 : MAIN METAL-C-B
Sub
A34 : DM VR 3 : SUB METAL-C-A
A34 : DM VR 3 : SUB METAL-C-B
Group delay
1RV303/DM-89, 1RV304/DM-89
Main
A33 : DM VR 2 : MAIN OXIDE-C-A
A33 : DM VR 2 : MAIN OXIDE-C-B
Sub
A34 : DM VR 3 : SUB OXIDE-C-A
A34 : DM VR 3 : SUB OXIDE-C-B
Group delay
1RV104/DM-89, 1RV103/DM-89
Main
A33 : DM VR 2 : MAIN OXIDE-Y-A
A33 : DM VR 2 : MAIN OXIDE-Y-B
Sub
A34 : DM VR 3 : SUB OXIDE-Y-A
A34 : DM VR 3 : SUB OXIDE-Y-B
A3F : NV-RAM CONTROL
n
This provisional adjustment explains how to adjust without using the network analyzer
as opposed to adjustment (Section 3-8-5) using the network analyzer.
Perform this provisional adjustment only when the network analyzer is not available for
an urgent maintenance. Be sure to perform the adjustment (Section 3-8-5) using the
network analyzer at a later date.
Remarks
TP100/DM-89
TP300/DM-89
TP300/DM-89
TP100/DM-89
Set the data to E4.
Set the data to D0.
TP104/DM-89
TP3/DM-89
NTSC model: Set the data AF.
PAL model:
TP2/DM-89
TP304/DM-89
TP7/DM-89
NTSC model: Set the data 70.
PAL model:
TP6/DM-89
TP304/DM-89
TP7/DM-89
TP6/DM-89
*1
TP104/DM-89
TP3/DM-89
TP2/DM-89
(Continue)