6. Cleaning Roller Position Adjustment
(1) Confirm visually that the cleaning roller does
not touch the upper drum. (Specification 1)
If the cleaning roller touches the upper drum,
bend portion B of the video head cleaner sub-
assembly in the direction indicated by arrow
C with portion A as a supporting point.
(2) Similarly, confirm visually that the cleaning
roller does not touch the terminal of the full-
erase head. (Specification 2)
If the cleaning roller touches the terminal of
the full-erase head, bend portion B of the
video head cleaner sub-assembly in the
direction indicated by arrow D with portion A
as a supporting point.
(3) Push the iron core of the solenoid in the
direction indicated by the arrow. At that
time, confirm that a clearance exists between
the cleaner lever and video head cleaner sub-
assembly. (Specification 3)
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
Full-erase head
Cleaning roller
B
A = Clearance exists
Spec.1:
B = Clearance exists
Spec.2:
1
H
2
H
3
H
Iron core
C
Spec. 3: C = Clearance exists
. Specifications are not satisfied.
Portion A
(Supporting point)
Video head cleaner
sub-assembly
Cleaning Roller Position Adjustment
5-26. Cleaning Solenoid Replacement
Upper drum
Video head
Lower drum
A
Claener lever
Video head cleaner
sub-assembly
Portion B
C
D
5-169