Siemens SITOP UPS1600 Equipment Manual page 115

Hide thumbs Also See for SITOP UPS1600:
Table of Contents

Advertisement

0x000A: Third-party battery parameters (reading/writing)
Data
Ignore data of coded battery
Battery type
Typical ambient temperature [°C]
Battery capacity [Ah/10]
End-of-charge voltage at 20 °C
[V/100]
Temperature coefficient [mV/K]
Duration of constant floating volt-
age charging phase [h]
Charge current [mA]
Start preserve charge voltage [V]
Stop buffering voltage [V/100]
Faulty battery voltage [V/100]
0x000B: Charging parameters (reading/writing)
Data
Deactivate charging function
Maximum permitted charge current
[mA]
0x0010: DC-UPS command (writing)
Data
CommandID
Parameter 1
Parameter 2
Data
CommandID
Parameter 1
Parameter 2
SITOP UPS1600 / BAT1600 / UPS1100
Equipment Manual, 07.2021, A5E37775406-11-76
Description
Ignore SITOP battery data: When this parameter is set to "1", SITOP
battery data is ignored, and instead data from the third-party bat-
tery parameter set is used.
Make/type of battery 0 = Pb ... lead-gel battery, 1 = pPb ... pure
lead battery
Typical ambient temperatures for battery modules in operation.
Total capacity of the installed batteries
Max. permissible battery voltage referred to 20 °C during the
charging phase. When reaching this threshold value, a switch is
made into the "Constant voltage" charging mode.
Together with the end-of-charge voltage at 20 °C, the temperature
coefficient is used in the system to calculate the temperature-
controlled end-of-charge voltage.
Duration of the constant voltage charging phase
Max. permissible charge current. The manufacturer's data for the
permissible charge current of the battery must be observed. The
lowest permissible charge current is applicable when several bat-
teries are connected.
Threshold when switching over from normal battery charging to
pure preserve charge voltage (brief post charging)
Discharge threshold at which buffer mode is stopped
Voltage value below which a battery is considered to be defective
and should no longer be charged
Description
Shutdown battery charging
Maximum permissible current to charge the battery
Description
Remote reset: 8195
Not used
T
: output voltage down time [s]
off
>= V1.0
Description
Remote reset 2: 8207
T
: Waiting time after end of communication [s]
d
T
: output voltage down time [s]
off
>= V2.0.0
Engineering and remote access
3.6 Cyclic and acyclic data
Data type
Unsigned8
Unsigned8
Integer8
Unsigned16
Unsigned16
Unsigned16
Unsigned16
Unsigned16
Unsigned16
Unsigned16
Unsigned16
Data type
Unsigned8
Unsigned16
Data type
Unsigned16
Unsigned8
Unsigned8
Data type
Unsigned16
Unsigned8
Unsigned8
115