Hearth and Home Technologies Expedition-I Manual page 60

Single burn rate wood-fired heater
Table of Contents

Advertisement

Client: HHT
Model: Expedition 1
Test Control Settings
Primary Air Setting(s):
Targeted Burn Category: N/A – Single Burn Rate
Preburn Notes
Time
14:15
Ignited kindling fire (7.7 lbs), fan on high.
14:39
@ 2.0 lbs of kindling remaining, loaded pre-burn test fuel, activated ACC.
15:57
@2.4 lbs, leveled coal bed and zeroed scale in preparation of fuel loading.
Test Notes
Test Burn Start Time:
Door Closed:
80
Other Loading Notes:
Time
0 min
Loaded test fuel, activated ACC, fan on high.
60 min
Changed 1
112 min
End of test
Test Burn End Time:
Calibration Gas Values:
Calibration Results:
Zero
11:07
Time
0.00
CO
2
0.00
CO
Flue Gas Probe Leak Check:
Technician Signature:
ASTM E2780 Wood Heater Run Sheets
Job Number: 21-661
Run Number: 2
Wood Heater Run Notes
N/A – Single Burn Rate
15:59
seconds
N/A
st
hour filter train.
17:51
Flue Gas Concentration Measurement
Span Gas
Mid Gas
Pre Test
Mid
Span
11:12
11:09
10.04
17.14
2.452
4.299
Initial: No Leakage
Notes
Test Fuel Loaded by:
Air Control Set at: 0
Notes
CO
(%): 17.14
CO (%): 4.3
2
CO
(%): 9.90
CO (%): 2.47
2
Zero
18:01
-0.14
-0.017
Final: No Leakage
Date: 5/14/21
Tracking #: 100
Test Date: 5/13/2021
40
seconds
seconds
Post Test
Mid
Span
18:03
18:04
9.95
17.09
2.481
4.393
Page 1 of 2