Hearth and Home Technologies Expedition-I Manual page 55

Single burn rate wood-fired heater
Table of Contents

Advertisement

Run 2.xlsm
BOX B TEST DATA - ASTM E2780 / ASTM E2515
Client:
HHT
Model:
Expedition 1
Run #:
2
Gas Meter
Elapsed
Sample
3
Time (min)
Rate (cfm)
(ft
)
96
20.943
0.219
97
21.162
0.219
98
21.380
0.218
99
21.599
0.219
100
21.817
0.218
101
22.036
0.219
102
22.256
0.220
103
22.475
0.219
104
22.695
0.220
105
22.915
0.220
106
23.134
0.219
107
23.353
0.219
108
23.572
0.219
109
23.791
0.219
110
24.010
0.219
111
24.229
0.219
112
24.448
0.219
Avg/Tot
24.448
0.218
PFS-TECO
Job #:
Tracking #:
Technician:
Date:
Particulate Sampling Data
Meter
Orifice dH
Meter
Vacuum
(in H
O)
Temp (°F)
2
(in Hg)
1.90
85
-3
1.90
85
-3
1.91
85
-3
1.91
85
-3
1.90
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.91
85
-3
1.90
83
-3.00
Page 15 of 19
21-661
100
SJB
5/13/2021
Flue Draft
Pro. Rate
Filter (°F)
(in H
(%)
101
87
98
87
100
87
101
87
98
87
101
87
98
87
100
87
101
87
99
87
100
86
100
87
98
86
100
86
100
87
100
86
100
86
100
86
-0.072
Flue Gas Data
CO
(%)
CO (%)
2
O)
2
-0.050
4.67
0.78
-0.050
4.59
0.82
-0.050
4.55
0.84
-0.050
4.51
0.86
-0.050
4.47
0.88
-0.050
4.44
0.91
-0.050
4.34
0.96
-0.050
4.30
0.96
-0.050
4.32
0.96
-0.050
4.19
0.98
-0.050
4.17
1.00
-0.050
4.13
1.00
-0.050
4.14
1.01
-0.050
4.12
0.99
-0.050
4.04
1.01
-0.050
4.39
0.88
-0.050
4.33
0.89
7.57
0.60