C. Mobile Home Approved (USA only)
• This appliance is approved for mobile home installations
when not installed in a sleeping room and when an
outside combustion air inlet is provided.
• The structural integrity of the mobile home floor, ceiling,
and walls must be maintained.
• The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
chimney must be listed to UL103 HT or a listed UL-1777
full length six inch (152mm) diameter liner must be used.
• Outside Air Kit, part OAK-ACC must be installed in a
mobile home installation.
D. Electrical Rating
Maximum 1.5 Amps (blower).
E. Glass Specifications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please contact
your dealer for replacement glass.
F. Non-Combustible Materials
Material which will not ignite and burn, composed of any
combination of the following:
- Steel
- Plaster
- Brick
- Iron
- Concrete
- Tile
- Glass
- Slate
Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace of 750° C.
G. Combustible Materials
Material
made
of/or
following materials:
- Wood
- Compressed Paper
- Plant Fibers
- Plastic
- Plywood/OSB
- Sheet Rock (drywall)
Any material that can ignite and burn: flame proofed or not,
plastered or non-plastered.
H. Sleeping Room
When an appliance is installed in a sleeping room an outside
air kit is required and it is recommended that a smoke and/
or CO alarm be installed in the bedroom. The size of the
room must be at least 50ft³ per 1,000 Btu/hr stove input
4
surfaced
with
any
I. California - Prop65
This product and the fuels used to operate this product (wood), and
the products of combustion of such fuels, can expose you to
chemicals including carbon black, which is known to the State of
California to cause cancer, and carbon monoxide, which is known to
the State of California to cause birth defects or other reproductive
harm. For more information go to: WWW.P65Warnings.ca.gov
• Installation and use of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not
approved by Hearth & Home Technologies.
• Operating appliance without fully assembling
all components.
• Operating appliance without legs attached (if supplied
with unit).
• Do NOT Over fire - If appliance or chimney connector
glows, you are over firing.
Any such action that may cause a fire hazard.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified
installer, service agency or your dealer.
of
the
Hearth & Home Technologies WILL NOT warranty stoves
that exhibit evidence of over-firing. Evidence of over-
firing includes, but is not limited to:
• Warped air tube
• Deteriorated refractory brick retainers
• Deteriorated baffle and other interior components
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifications and/or price without notice.
7094-802A
WARNING
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
04/21