Emissions Sampling System Thermocouple Calibration Check
Calibration based on NIST Monograph 175 per ASTM E2515-11
Date: 3/12/2021
Performed By: S. Button
Reference
Acceptable
Temperature
Error (F)
(F)
± 4.0
0
± 4.0
200
± 4.0
400
± 4.5
600
± 6.0
800
Reference
Acceptable
Temperature
Error (F)
(F)
± 4.0
0
± 4.0
200
± 4.0
400
± 4.5
600
± 6.0
800
Technician Signature:
PFS-TECO
All thermocouples are type "K"
Calibration Instrument ID Number:
Thermocouple Location
FB
FB
FB
Left
Right
Back
-0.9
-0.9
-0.9
199.0
199.0
199.0
399.0
398.9
399.0
599.0
598.9
599.0
799.0
798.9
799.0
Thermocouple Location
Filter
Ambient
A
-1.3
-0.7
198.6
199.3
398.6
399.2
598.7
599.3
798.6
799.2
Sampling System ID Numbers: 129/130
FB
FB
Top
Bottom
-1.2
-1.3
198.8
198.7
398.8
398.6
598.8
598.7
798.7
798.7
Filter
Meter A
B
0.0
-1.0
200.4
199.0
400.2
399.0
600.1
599.0
799.9
798.9
Date: 3/12/2021
165
Catalyst
Flue
Exit
-0.8
-0.5
199.1
199.4
399.1
399.3
599.2
599.4
799.1
799.4
Dilution
Meter B
Tunnel
-1.2
-0.3
198.8
199.6
398.7
399.6
598.8
599.6
798.7
799.5

Advertisement

Table of Contents
loading