Run 1.xlsm
TEST RESULTS - ASTM E2780 / ASTM E2515
Client:
HHT
Model:
Expedition 1
Run #:
1
Average Gas Velocity in Dilution Tunnel (ft/sec)
Average Gas Flow Rate in Dilution Tunnel (dscf/hr)
Particulate Concentration, dry-standard (g/dscf)
Difference from Average Total Particulate Emissions (g)
Difference from Average Total Particulate Emissions (%)
Difference from Average Emissions Factor (g/kg)
Quality Checks
Dual Train Precision
Filter Temps
Face Velocity
Leakage Rate
Ambient Temp
Negative Probe Weight Evaluation
Pro-Rate Variation
Stove Surface Δ
T
PFS-TECO
Burn Rate (kg/hr):
Total Sample Volume (ft
Average Gas Meter Temperature (°F)
Total Sample Volume (dscf)
Average Tunnel Temperature (°F)
Total Time of Test (min)
Total Particulate Catch (mg)
Total PM Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
Final Average Results
Total Particulate Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
HHV Efficiency (%)
LHV Efficiency (%)
CO Emissions (g/min)
Requirement
Each train within 7.5% of average emissions (in
grams), or emission factors within 0.5 g/kg
<90 °F
< 30 ft/min
Less than 4% of average sample rate
55-90 °F
<5% of Total Catch
90% of readings between 90-110%; none greater than
120% or less than 80%
<126°
Page 2 of 17
Technician:
2.29
Ambient
Sample
Sample
Train A
3
)
16.689
21.640
78.6
16.562
21.300
0.0
0.0000000
0.0000798
0.00
0.00
-
-
-
-
2.57
1.64
0.72
64.3%
69.5%
2.66
Observed
See Above
0.001 cfm
Min: 75 / Max: 79.7
Probe Catch Not
Negative
See Data Tabs
F
Job #:
21-661
Tracking #:
100
SJB
Date:
5/13/2021
Sample
1st Hour Filter
Train B
21.758
8.7
22571.5
81.8
80.4
21.395
102.4
94
1.7
1.4
0.0000654
2.82
2.31
1.80
1.48
0.79
0.65
0.25
0.25
9.9%
9.9%
0.07
0.07
Result
OK
OK
89.2
OK
12.8
OK
OK
OK
OK
OK
46.8
13.634
79.3
13.481
1.3
0.0000964
2.18
2.18
-
-
-
-