Hearth and Home Technologies Expedition-I Manual page 51

Single burn rate wood-fired heater
Table of Contents

Advertisement

Run 2.xlsm
BOX A TEST DATA - ASTM E2780 / ASTM E2515
Client:
HHT
Model:
Expedition 1
Run #:
2
Elapsed
Gas Meter
Sample
Time
3
Rate (cfm)
(ft
)
(min)
96
21.540
0.227
97
21.765
0.225
98
21.992
0.227
99
22.219
0.227
100
22.445
0.226
101
22.671
0.226
102
22.898
0.227
103
23.126
0.228
104
23.351
0.225
105
23.578
0.227
106
23.806
0.228
107
24.033
0.227
108
24.259
0.226
109
24.486
0.227
110
24.714
0.228
111
24.939
0.225
112
25.166
0.227
Avg/Tot
25.164
0.225
PFS-TECO
Job #:
Tracking #:
Technician:
Date:
Particulate Sampling Data
Dilution
Orifice
Meter
Tunnel dP
dH
Temp (°F)
(in H
O)
(in H
O)
2
2
0.020
1.90
91
0.021
1.90
91
0.020
1.90
91
0.020
1.90
91
0.021
1.90
91
0.020
1.90
90
0.021
1.90
91
0.020
1.90
91
0.020
1.90
91
0.021
1.90
91
0.020
1.90
91
0.020
1.90
91
0.021
1.90
91
0.020
1.90
91
0.020
1.91
91
0.020
1.90
91
0.020
1.90
92
0.021
1.87
86
21-661
100
SJB
5/13/2021
Fuel Weight (lb)
Meter
Pro. Rate
Scale
Vacuum
(%)
Reading
(in Hg)
-3
101
0.3
-3
97
0.3
-3
101
0.3
-3
101
0.3
-3
98
0.2
-3
100
0.2
-3
98
0.2
-3
101
0.2
-3
100
0.2
-3
98
0.1
-3
101
0.1
-3
101
0.1
-3
98
0.1
-3
101
0.1
-3
101
0.0
-3
100
0.0
-3
101
0.0
-3.00
100
Page 11 of 19
Temperature Data (°F)
Weight
Dilution
Flue
Filter
Change
Tunnel
-0.03
94
338
85
-0.01
94
338
85
-0.03
94
337
85
-0.03
94
336
85
-0.02
93
336
85
-0.02
93
334
85
-0.02
93
332
85
-0.02
93
331
85
-0.02
93
329
85
-0.02
93
328
85
-0.02
93
327
85
-0.02
93
326
85
-0.02
93
326
85
-0.02
93
325
85
-0.02
93
324
85
-0.02
93
324
85
-0.03
93
324
85
102
480
85
Ambient
81
81
81
81
81
81
81
81
81
81
81
81
81
81
81
81
81
79.6

Advertisement

Table of Contents
loading

Table of Contents