Test Conditions Summary; Appliance Operation And Test Settings - Hearth and Home Technologies Expedition-I Manual

Single burn rate wood-fired heater
Table of Contents

Advertisement

Test Conditions Summary

Testing conditions for all runs fell within allowable specifications of ASTM E2780 and
ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below.
Ambient (°F)
Runs
Pre
Post
1
75
78.8
2
79
80.8

Appliance Operation and Test Settings

The appliance was operated according to procedures as described in the Operations
Manual, found in Appendix B submitted with this report. Detailed run information can be
found in Appendix A submitted with this report.
Pre-Burn Air Setting
Automatic Combustion Control (ACC) Activated
Run 1
upon fuel loading, fan on high
Automatic Combustion Control (ACC) Activated
Run 2
upon fuel loading, fan on high
Page | 9
Average
Relative
Barometric
Humidity (%)
Pressure
(In. Hg.)
Pre
Post
43.1
36.7
30.00
30.5
30.1
29.92
Project # 21-661
Preburn
Test Fuel
Fuel
Weight
Weight
(lbs)
(lbs)
9.35
9.50
9.55
9.77
Test Run Air and Fan Settings
Automatic Combustion Control (ACC) Activated upon fuel
loading, fan on high
Automatic Combustion Control (ACC) Activated upon fuel
loading, fan on high
Model: Expedition-I
Test Fuel
Test Run
Moisture
Time
(%DB)
(Min)
21.6
94
21.6
112