Model: Expedition 1
Test Control Settings
Primary Air Setting(s):
Targeted Burn Category: N/A – Single Burn Rate
Preburn Notes
Time
10:30
Ignited kindling fire (7.5 lbs), fan on high.
11:01
@ 2.0 lbs of kindling remaining, loaded pre-burn test fuel, activated ACC.
12:01
@2.3 lbs, leveled coal bed and zeroed scale in preparation of fuel loading.
Test Notes
Test Burn Start Time:
Door Closed:
80
Other Loading Notes:
Time
0 min
Loaded test fuel, activated ACC, fan on high.
60 min
Changed 1
94 min
End of test
Test Burn End Time:
Calibration Gas Values:
Calibration Results:
Zero
11:07
Time
0.00
CO
2
0.00
CO
Flue Gas Probe Leak Check:
Technician Signature:
ASTM E2780 Wood Heater Run Sheets
Job Number: 21-661
Run Number: 1
Wood Heater Run Notes
N/A – Single Burn Rate
12:03
seconds
N/A
st
hour filter train.
13:37
Flue Gas Concentration Measurement
Span Gas
Mid Gas
Pre Test
Mid
Span
11:12
11:09
10.04
17.14
2.452
4.299
Initial: No Leakage
Notes
Test Fuel Loaded by:
Air Control Set at: 0
Notes
CO
(%): 17.14
CO (%): 4.3
2
CO
(%): 9.90
CO (%): 2.47
2
Zero
See Run #2 Notes
N/A
N/A
Final: No Leakage
Date: 5/13/21
Tracking #: 100
Test Date: 5/13/2021
45
seconds
seconds
Post Test
Mid
Span
N/A
N/A
N/A
N/A
Page 1 of 2