NOTE: Clearances may only be reduced by means approved by the regulatory authority having
jurisdiction
A. Sample of Serial Number / Safety Label
LOCATION: UNDER ASH LIP, PULL OUT TO VIEW
Test Lab &
Report Number
2
and Welcome to the Quadra-Fire Family
LISTED ROOM HEATER, SOLID FUEL TYPE
"For Use with Solid Wood Fuel Only."
Also for use in Mobile Home.
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation, venting and
operating instructions. CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS
ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA
Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling. WARNING - For Mobile Homes: Do
not install in a sleeping room. An outside combustion air inlet must be provided and
unrestricted while unit is in use. The structural integrity of the mobile home floor,
ceiling and walls must be maintained. The insert must be properly grounded to the
frame of the mobile home. A complete relining of the chimney system with a 6 inch
(152mm) diameter listed stainless liner is required. Must be equipped with a spark
arrestor cap. Outside Air comes standard on the insert and must be installed before
operating insert.
When used as a masonry insert stove, install only in a masonry fireplace built to
national and/or local codes. Do not remove brick or mortar to accommodate insert.
Installation requires a 5 foot minimum length of a starter pipe into existing chimney with
airtight face seal. A full reline with listed liner strongly reccomended.
Install only on a non-combustible hearth.
Approved for installation and use in factory built zero-clearance fireplaces conforming
to minimum fire chamber specifications. A complete relining of the chimney system with
a 6 inch (152mm) diameter listed stainless liner is required.
In Canada a full length
6 inch (152mm)
S635 flue liner is required as per ULC S628-93.
WARNING - Inspect and clean chimney frequently. Under certain conditions of use,
creosote buildup may occur rapidly. Do not connect this unit to a chimney serving another
appliance. DANGER: Risk of electrical shock. Disconnect power supply before
servicing. Route power cord away from unit. Do not route cord under or in front of
appliance. Electrical Rating: 115 VAC 1.4 AMPS 60 Hz
Do not use grate or elevate fire. Build wood fire directly on hearth (firebrick). Do not
overfire. If heater or chimney connector glows, you are overfiring. Operate only with doors
closed. Open only to add fuel to the fire. Replace glass only with 5mm ceramic
available from your dealer.
Maximum Mantel Depth - 12 inch (305mm)
Mantel
B
B
C
C
A
A
Insert
Fuel Door
E
E
F
F
Hearth Extension
Minimum Clearances To Combustible Material
Masonry, Heat Circulating &
Factory-Built
Refer to Clearances on other label for Canada
USA ONLY
A
Sidewall to Fuel Loading Door
13.5 in.
B
Mantel to Bottom of unit
47.75 in.
C
Top Trim to Bottom of unit
34.75 in.
D
Side Trim to Fuel Loading Door
13 in.
E
Hearth Extension from Glass
16 in.
F
Hearth Extenson from Fuel Loading Door
8 in.
CAUTION:
TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS.
NAMEPLATE AND INSTRUCTIONS.
R
EXPEDITION I
XXXXXXXXX
XXXXXXXXX
CONFORMS TO UL STD 1482 AND CERTIFIED TO ULC STD S628
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 crib wood particulate emission standards for single burn rate heaters. This single burn rate
wood heater is not approved for use with a flue damper.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner's manual for further
information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner's manual.
Mfg by:
2021 2022
JAN FEB MAR APR MAY JUN
2023
JUL AUG SEP OCT NOV DEC
352 Mountain House Road
Halifax, PA 17032
www.quadrafire.com
DO NOT REMOVE THIS LABEL
7094-803A
!
Fascia
or Trim
D
D
Factory-Built
Floor
Protection under Hearth
Extension
Thermal & Ember Protection
Floor height
0 to 4.5
inches below
Insert Base: Materials with R value of
2.9
required.
Ember Protection Only
Greater than
4.5
inches below Insert
Base.
HOT
WHILE
IN
OPERATION
DO
NOT
SEE
Serial No. / N° de série
HF
BARCODE LABEL
Made in U.S.A. of US and
imported parts.
Serial Number
Model Name
Mfg Date
04/21

Advertisement

Table of Contents
loading

Table of Contents