Run 2.xlsm
DILUTION TUNNEL & MISC. DATA - ASTM E2780 / E2515
Client:
HHT
Model:
Expedition 1
Run #:
2
Test Start Time: 15:59
Total Sampling Time (min):
Recording Interval (min):
Meter Box γ Factor:
Meter Box γ Factor:
Meter Box γ Factor:
Induced Draft Check (in. H
Smoke Capture Check (%):
Date Flue Pipe Last Cleaned:
Traverse Data
dP (in H
Point
1
0.012
2
0.018
3
0.020
4
0.020
5
0.018
6
0.012
7
0.012
8
0.014
9
0.020
10
0.020
11
0.018
12
0.010
Center
0.020
-0.062 in. H
Static Pressure:
Firebox Front
PFS-TECO
Tracking #:
Technician:
112
1
1.003 (A)
0.999 (B)
1.010 (Ambient)
O):
0
2
100%
5/13/2021
DILUTION TUNNEL FLOW
O)
Temp (°F)
2
101
101
101
101
101
101
101
101
101
101
101
101
101
O
2
TEST FUEL PROPERTIES
Fuel Load Configuration
Firebox Side View
Job #:
21-661
100
SJB
Date:
5/13/2021
Barometric Pressure (in. Hg)
Relative Humidity (%)
Room Air Velocity (ft/min)
Scale Audit (lbs)
Ambient Sample Volume:
Sample Train Post-Test Leak Checks
(A)
0.002
(B)
0.001
0.001
(Ambient)
Dilution Tunnel H
Tunnel Diameter:
Pitot Tube Cp:
Dilution Tunnel MW(dry):
Dilution Tunnel MW(wet):
Tunnel Area:
V
V
scent
Initial Tunnel Flow:
Firebox Back
Page 5 of 19
Pre-Test
Post Test
29.93
29.90
30.5
30.1
0
10.0
10.0
20.158 ft
cfm @
cfm @
cfm @
O:
2.00 percent
2
12 inches
0.99 [unitless]
29.00 lb/lb-mole
28.78 lb/lb-mole
2
0.7854 ft
:
8.62 ft/sec
strav
:
9.66 ft/sec
F
:
0.893 [ratio]
p
374.8 scf/min
Actual Fuel Used Properties
Fuel Type:
D. Fir
HHV (kJ/kg)
19,810
%C
48.73
%H
6.87
%O
43.9
%Ash
0.5
MC (%DB)
21.6
Avg.
29.92
0
3
-5 in. Hg
-5 in. Hg
-5 in. Hg