Hearth and Home Technologies Expedition-I Manual page 28

Single burn rate wood-fired heater
Table of Contents

Advertisement

Run 1.xlsm
WOODSTOVE PREBURN DATA - ASTM E2780
Client:
HHT
Model:
Expedition 1
Run #:
1
Recording Interval (min):
Run Time (min):
Elapsed
Scale
Flue Draft
Time
Reading
(in H
(min)
(lbs)
45
3.6
-0.090
46
3.4
-0.090
47
3.3
-0.090
48
3.2
-0.090
49
3.1
-0.090
50
3.0
-0.090
51
2.9
-0.090
52
2.8
-0.090
53
2.7
-0.080
54
2.6
-0.080
55
2.6
-0.080
56
2.5
-0.080
57
2.5
-0.080
58
2.4
-0.080
59
2.4
-0.070
60
2.3
-0.070
PFS-TECO
1
60
FB Left
FB Right FB Back
O)
2
341
300
344
304
346
307
349
311
351
315
354
319
356
323
359
326
361
330
363
333
364
337
365
339
367
342
368
345
370
348
372
351
Tracking #:
Technician:
Temperatures (°F)
FB Top
FB Bottom
326
495
326
495
325
493
329
491
332
490
336
487
339
485
344
477
347
473
347
467
346
458
345
450
342
443
338
431
335
419
330
410
Page 7 of 17
Job #:
21-661
100
SJB
Date:
5/13/2021
Stove
Surface
Flue
Average
201
332.5
595
202
333.9
593
203
334.7
589
203
336.6
581
204
338.3
576
205
340.3
565
206
341.8
552
206
342.6
538
207
343.6
530
207
343.4
517
208
342.6
503
209
341.6
492
210
340.5
473
211
338.8
456
211
336.6
443
212
335.1
432
Ambient
72
72
72
72
72
72
72
72
72
72
73
73
74
74
74
75

Advertisement