Results; Summary Table - Hearth and Home Technologies Expedition-I Manual

Single burn rate wood-fired heater
Table of Contents

Advertisement

Results

The average emissions rate for the 2 run test series was measured to be 1.9 g/hr with a
Higher Heating Value efficiency of 65%. The average CO emission rate for the 2 tests was
2.54 g/min. The HHT model Expedition-I
the 2020 crib wood PM emission standard of ≤ 2.0 g/hr per CFR 40 part 60, §60.532 (c).
Detailed individual run data can be found in Appendix A submitted with this report.

Summary Table

Overall Efficiency (% HHV)
CO Emissions (g/MJ Output)
CO Emissions (g/kg Dry Fuel)
Emissions Rate – First Hour (g/hr)
Particulate emission average of 2 test runs: 1.9 grams per hour.
Weighted average HHV efficiency of 2 test runs: 65%.
Average CO emissions of 2 test runs: 2.54 g/min.
Page | 7
Expedition-I
Date
Run Number
Emission Rate (g/hr)
Burn Rate (kg/hr)
Heat Output (Btu/hr)
CO Emissions (g/min)
Project # 21-661
Wood-Fired Room Heater meets
Run 1
Run 2
5/13/2021
5/13/2021
1
1.64
2.29
27,361
23,747
64.3%
64.9%
5.53
70.46
74.49
2.66
2.18
Model: Expedition-I
2
2.12
1.99
5.80
2.42
3.30

Advertisement