Test Run Narrative; Run 1; Run 2 - Hearth and Home Technologies Expedition-I Manual

Single burn rate wood-fired heater
Table of Contents

Advertisement

Test Run Narrative

Run 1

Run 1 was performed on 5/13/2021, in accordance with the procedures specified in ASTM
E2780 for a single burn rate appliance. The total test time was 94 minutes. The particulate
emissions rate for the test was 1.64 g/hr, the burn rate was 2.29 kg/hr with an HHV
efficiency of 64.3%. The Train A sample assembly was changed at 1 hr to determine 1
hour emissions. All test results were appropriate and valid. There were no anomalies and
all test criteria were met.

Run 2

Run 2 was performed on 5/13/2021, in accordance with the procedures specified in ASTM
E2780 for a single burn rate appliance. The total test time was 112 minutes. The
particulate emissions rate for the test was 2.12 g/hr, the burn rate was 1.99 kg/hr with an
HHV efficiency of 64.9. The Train A sample assembly was changed at 1 hr to determine
1
hour emissions. All test results were appropriate and valid. There were no anomalies
st
and all test criteria were met.
The average burn rate for the two test runs is 2.14 kg/hr, with each test run differing from
the average by 7.0%, which meets the requirement for single burn heaters in ASTM E2780
X1.4.2.