11 PROGRAMMING
The machine can be programmed via the unit and
Autosteamer button panels.

11.1 PROGRAMMING AND READINGS

A
(K1)
C
(K3)
F
(K6)
1
2
3
4
The quantity of dispensed coffee can be
programmed for all buttons.
IMPORTANT: when the left button
panel is programmed (unit number
1), the programmed doses are
automatically transferred to the
other button panels.
You can customise the coffee doses for each
dispensing unit.
PROGRAMMING COFFEE DOSES
Start the machine as described in the relevant
paragraph.
Program the doses as follows:
• Fit the filter holder with coffee on the left unit
of the machine, as shown in the paragraph
"OPERATION".
• Position a cup or two cups under the unit
according to the type of programming to be
performed.
(K2)
(K4)
G
(K7)
E
(K5 ENTER)
• Press button (E) of unit 1 for more than 10
seconds and check that the LED switches from
steady to flashing. The following screen will be
displayed:
B
D
• Within 30 seconds, press the dispensing button
to be programmed, e.g. button (A) (single
espresso coffee).
During dispensing the LEDs of buttons (A) and
(E) remain lit, the other buttons go off.
The seconds counter displays the time in
progression.
• When the coffee reaches the desired quantity
in the cup, press any button on the button panel
to stop dispensing; the quantity of dispensed
coffee for that button will be saved, the button
(A) turns off while the other buttons that still
need to be saved turn on.
• If necessary, repeat the aforementioned
operations to program the other buttons as well;
after 30 seconds without using any button, the
dose programming stage will be quitted.
PROGRAMMING CONTINUOUS DOSE
You can also programme the continuous dose on
buttons (E). The programming procedure is the same
as for the other 4/6 doses of each button panel
described above. During programming, only the LED
of the continuous button being programmed remains
lit.
If Purge is enabled, press the (E) button twice to start