Communicator Configuration
7.7.3
Configure Frame Field Settings
Procedure
1.
In the Transaction templates list, select a transaction template to configure.
2.
In the Transaction template settings select a Field to configure.
The Field sidebar opens, on the right side of the screen.
3.
Configure the Field settings.
Limit can only be added as a Response frame field.
Node address
Frame field representing the Node address of the node. A constant byte that holds a copy of the
nodes address when the transaction is used by a node.
When the transaction template is used by a node, the Node address field will automatically be
replaced with the actual node address of the node.
Constant
Name: You can name the Frame Field to make it easier to identify.
Type: Specify the number of bytes in the frame. Select Byte (1 byte) (Default), Word (2
bytes), Double word (4 bytes), Array of bytes or String.
Endianess: Select Big-endian (Default) or Little-endian.
Fixed field*: Select Yes, set here (Default) or No, set when used.
Length: Valid for Array of bytes. Enter a byte offset value between 0 and 32 byte. Default
value is 1 byte. Enter a Value for each Byte (0–31).
Value: The value of the Constant in the frame. Enter a value between 0 (Default) and 255.
Min value: Specify the minimum value that can be set when the template is used.
Max value: Specify the maximum value that can be set when the template is used.
Default value: Default value set when the template is used.
®
Anybus
Communicator
User Manual
52 (124)
SCM-1202-162 1.1 en-US