Use Cases
10.3.3
Choose Serial Protocol Type
The Barcode Scanner is using a produce/consume protocol to access parameters addressed with
index and sub index.
On the Serial RS232/485 page, select Custom Produce/Consume.
10.3.4
Set Up Serial Communication
Set up the communication between the Communicator and the Barcode Scanner.
In the Serial RS232/485 page, configure the Communication settings.
Used the following settings:
Frame fields
Physical standard
Baud rate
Data bits
Parity
Stop bits
®
Anybus
Communicator
User Manual
Value
RS-232
9600 baud
8 bits
1
1 stop bit
103 (124)