Technical description

Protection equipment

7.3
LPTC-600 sensor
7.3.1
Temperature
T/°C [%/K]
[°C]
-40
-30
-20
-10
0
10
20
25
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
36
───
The temperature sensor LPTC-600 is installed in all servo drives of
the AMI812x series.
The LPTC-600 is integrated into the monitoring system of the servo
drive when using the pre-assembled cable. Configure the servo
drive according to the temperature warning at 120 °C and the
switch-off temperature at 140 °C.
The LPTC-600 is identical to the KTY 84,130 used previously.
The following table shows the resistance values of the temperature
sensor:
minimum
0.84
340
0.83
370
0.82
403
0.80
437
0.79
474
0.77
514
0.75
555
0.74
577
0.73
599
0.71
645
0.70
694
0.68
744
0.66
797
0.64
852
0.63
910
0.61
970
0.60
1029
0.58
1089
0.57
1152
0.55
1216
0.54
1282
0.53
1350
0.52
1420
0.51
1492
AMI8100
LPTC-600
Resistance [Ω]
Nominal value
maximum
359
391
424
460
498
538
581
603
626
672
722
773
826
882
940
1000
1062
1127
1194
1262
1334
1407
1482
1560
Temperature er-
ror [K]
379
± 6.48
411
± 6.36
446
± 6.26
483
± 6.16
522
± 6.07
563
± 5.98
607
± 5.89
629
± 5.84
652
± 5.79
700
± 5.69
750
± 5.59
801
± 5.47
855
± 5.34
912
± 5.21
970
± 5.06
1030
± 4.90
1096
± 5.31
1164
± 5.73
1235
± 6.17
1309
± 6.63
1385
± 7.10
1463
± 7.59
1544
± 8.10
1628
± 8.62
Version: 1.0

Advertisement