Download Print this page

Heartland VALUE Series Assembly Manual page 25

Hide thumbs Also See for VALUE Series:

Advertisement

PARTS REQUIRED:
x2
x2
7/16 x 41-7/8 x 96"
7/16 x 45-1/8 x 96"
(1,1 x 106 x 244 cm)
(1,1 x 115 x 244 cm)
x2
x2
7/16 x 23-7/8 x 45-1/8"
7/16 x 23-7/8 x 41-7/8"
(1,1 x 61 x 106 cm)
(1,1 x 61 x 115 cm)
Roof panels may cause serious injury
until securely fastened.
You must square the roof by attaching one panel fist. You will use the panels' long
edge as a lever to bring your roof into square. Commonly known as "racking".
BEGIN
1
Attach the 45-1/8 x 96" panel with the
rough side up (painted-grid lines side) with
a 3/4" measurement on the rafter (Fig B)
and the panel flush at the peak (Fig. A).
Secure panel with two 2" nails in the
corners.
Move to the opposite end. Using the long
2
edge of the panel as a lever move the
panel side-to-side until the top corner is
flush to the peak (Fig. C) and there is 1/4"
measurement to the gable trim (Fig. D).
You may need to move your backwall to
get the 1/4" measurement. Secure panel
with two 2" nails in the corners.
ROOF PANELS
2" (5 cm) x196
3/4"
GAUGE
BLOCK
Flush at peak.
Fig. A
Two Nails
Gauge
Block
Fig. B
Flush at peak.
3/4"
(1,9 cm)
Fig. C
1/4"
(6 mm)
Gable
Trim
1/4"
Fig. D
(6 mm)
44
PARTS REQUIRED:
3/4"
GAUGE BLOCK
Keep spacing between the center of
3
the rafters at the lower edge of the
panel and secure with one 2" nail into
each rafter (Fig. E).
Move to the top of the panel and keep
spacing between the center of the
rafters. Secure with one 2" nail into
each rafter (Fig. E).
Nail the roof panel using 2" nails 6"
apart on edges and 12" apart inside
panel.
Attach the second 23-7/8 x 45-1/8"
upper roof panel flush to first panel,
flush at peak and with the 1/4"
measurement (Fig. F, G).
22-1/4"
(56,5 cm)
Fig. E
Attach the lower gable panels flush to the
4
upper panels (Fig. H) and 3/4" on rafter
(Fig. I) and with a 1/4" measurement at
the gable trim (Fig. J).
Nail the roof panel using 2" nails 6" apart
on edges and 12" apart inside panel.
Repeat process to attach roof panels
on the opposite side.
Fig. I
ROOF PANELS
6" (15 cm)
12"
(30,5 cm)
1/4"
(6 mm)
7/16 x 23-7/8 x 45-1/8"
Fig. G
(1,1 x 61 x 115 cm)
Gable Trim
NOTE:
Measurements from inside of panels
24"
24"
24"
22-1/4"
(61 cm)
(61 cm)
(61 cm)
(56,5 cm)
2" Nail
23-7/8"
(61 cm)
3/4"
(1,9 mm)
96"
(244 cm)
Fig. J
3/4"
1/4"
(1,9 mm)
(6 mm)
45
Flush
Fig. F
Flush
Fig. H
Gable
Trim

Advertisement

loading

Related Products for Heartland VALUE Series